Tianjin Youyi ECT Dual-Plane Sensor System
TJUECT-E12x2: Dual-plane 24-electrode ECT sensor with 276-channel full-combination measurement; non-invasive Electrical Capacitance Tomography for 2D/3D real-time imaging and quantitative analysis of multiphase flow in pipes. 3D acquisition at 200 Hz and above, fF-level signal capture.
The Tianjin Youyi ECT Dual-Plane Sensor System uses non-invasive Electrical Capacitance Tomography (ECT) with dual-plane 24 electrodes for 2D/3D real-time imaging and quantitative analysis of multiphase flow in pipes. The sensor does not intrude into the fluid or disturb the flow field; it supports oil-water and other multiphase combinations and is suitable for industrial process monitoring and research.
Demo
Overview
Dual-plane 24 electrodes · high-speed 3D real-time imaging
The dual-plane layout captures not only the phase distribution of a single cross-section but also derives dynamic parameters such as velocity distribution through dual-plane correlation analysis. The system performs 2D/3D tomographic data acquisition, real-time reconstruction and online detection, outputting quantitative parameters including phase fraction, phase interface and phase velocity.
-
Dual-plane 24 electrodes · 276 channels
Dual-plane layout, 12 electrodes per plane, 24 ECT electrode plates in total; 24 electrodes in pairwise combination yield 276 independent measurement channels.
-
High-speed 3D real-time imaging
3D tomographic data acquisition at ≥ 200 Hz with image refresh ≥ 20 Hz; 2D/3D real-time reconstruction and online detection.
-
fF-level high-resolution acquisition
fF-level signal acquisition with ±1% dynamic-range stability, capturing minute dielectric changes.
-
Non-invasive · multiphase compatible
Wall-mounted sensor, non-intrusive and non-disturbing to the flow; supports oil-water and other phase combinations.
Specifications
Electrode configuration
Dual-plane, 12 electrodes per plane, 24 ECT plates in total.
Detection channels
276 (max simultaneous measurement points).
Measurement range
0.1 – 10 pF.
3D acquisition frequency
≥ 200 Hz; image refresh ≥ 20 Hz.
Signal level
fF-level; dynamic-range stability ±1%.
Size
DN50, flanged; pressure ≥ 3 MPa, temperature ≥ 80 ℃.
3D reconstruction voxels
≥ 8000; slice browsing in X/Y/Z, ≥ 20 slices per direction.
Data export
mat / csv / dat; images png / jpg / tiff; video mp4; secondary-development interface provided.
Gallery
Companion Software
Imaging / reconstruction software that pairs with this instrument